Influence of interfering parameters on the results of continuity control of coatings by the electric spark method

封面

如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The analysis of the influence of the surface roughness of the electrically conductive base and partial discharges on the process of testing dielectric coatings by the electrospark method is given. The simulation results and the obtained dependencies made it possible to formulate proposals regarding the operating modes of the equipment and the principles of fixing the discharge current, which reduce their influence on the reliability of the control.

作者简介

I. Gnivush

Saint Petersburg Mining University;CONSTANTA Ltd

Email: kin4_g@mail.ru
St. Petersburg, Russia

V. Syasko

Saint Petersburg Mining University;CONSTANTA Ltd

Email: 9334343@gmail.com
St. Petersburg, Russia

A. Musikhin

CONSTANTA Ltd

Email: musihinaleksei@mail.ru

参考

  1. Киселев В.Г., Рузич Е.Н. Диэлектрические покрытия и их влияние на защиту от коррозии наружной поверхности подземных трубопроводов // Проблемы энергетики. 2018. № 1. С. 80-89.
  2. Редько В.В., Старикова Н.С. Выявляемость дефектов изоляции кабельных изделий при испытаниях высоким напряжением // Контроль. Диагностика. 2014. № 12. С. 69-73.